How to fix the error that preselected objects are not selected when moved out of the screen in AutoCAD?
Set up annotation scale list only display metric units in AutoCAD
OK. It’s so easy with a variable in AutoCAD. Do step by step as follows:
- Step 1: SELECTOFFSCREEN > Enter;
- Step 2: Input value 1 > Enter to finish and now enjoy your result.
Value Description
0 Off-screen selection is off
1 Off-screen selection is on with the limitations of mouse input support only. Also, zoom/pan will hit some limitations during the selection.
2 Off-screen selection on without limitation
NOTE: When you set SELECTIONOFFSCREEN to 2, there may be a possibility that the selection results are incorrect. This is meant for experimental purpose only.
Thanks for reading. Good luck to you!